Programming
27
Programming With The Programming Key
The Programming Key (CC891) is a unique device that will allow you to store or copy
programming information from your control panel. Once the programming key has
information stored in the microprocessor, the programming key may be used to easily program
other existing
Solution 862
control panels with the same programming data, or be
alternatively used for back up purposes of existing information.
Connecting a programming key, which has been pre-programmed directly onto the control
panel in the disarmed state, will automatically initiate a data transfer from the programming
key to the control panel memory.
If you have a new programming key, you should first enter the Installer's Programming Mode
and program the system as required before connecting the programming key to the control
panel.
To connect the programming key, locate the socket marked PROGRAMMING KEY found at
the top of the PCB (printed circuit board) next to the Auxiliary Module socket. Observe the
triangular markings on the printed circuit board and line them up with the markings on the
programming key.
To copy the control panel's data into the programming key, access Installer’s Programming
Mode (e.g.
1234
followed by the
#
button) and enter Installer’s Programming
Command
962
followed by the
#
button. Refer to Command 962 - Copy Control Panel
Memory To Programming Key on page 34 for further information.
To exit the Installer's Programming Mode, enter command
960
followed by the
#
button. Two beeps will be heard and the system will return to the disarmed state. Before
removing the programming key, wait two seconds for the activity LED to return to its normal
state. The programming key will now become your standard data pattern for future
programming of your control panels.
It should be noted that when entering the Installer's Programming Mode, inserting a
programming key and then changing any location will cause a simultaneous update of not only
the programming keys data, but also the control panels data. Therefore, you are not able to
change data in the programming key without the same location being changed in the control
panels memory.
Connecting a Programming Key (CC891) to the control panel when the programming
keys memory is blank will corrupt the control panel's memory unless the Installer's
Programming Mode has been entered first. If this occurs, then the control panel will
need to be returned to Electronics Design and Manufacturing Pty Limited where a service
fee will be charged to unlock the control panel's memory.
Electronics Design and Manufacturing Pty Limited
ISSUE130
Summary of Contents for Solution 862
Page 1: ...Solution 862 Installation Manual ISSUE 1 30...
Page 2: ......
Page 4: ......
Page 6: ......
Page 74: ...74 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 118: ...118 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 149: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 154: ...154 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 188: ...188 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 212: ...212 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 228: ...228 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 240: ...240 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 245: ...Programming Sheets...
Page 254: ...254 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 255: ...Index...
Page 262: ......