![EDM Solution 862 Installation Manual Download Page 163](http://html1.mh-extra.com/html/edm/solution-862/solution-862_installation-manual_2362278163.webp)
Zone Information
163
2
3
4
5
6
7
8
9
10
Delay-1 Zone
A Delay-1 zone (Contact ID Event Code 130) will have a delay time determined by the value
in Entry Timer 1 on page 204. After entry time has expired, the system will activate into alarm
condition.
If a Delay-1 zone has not restored at the time the system is disarmed, a zone restore report will
be automatically sent to the receiving party.
Delay-2 Zone
A Delay-2 zone (Contact ID Event Code 130) will have a delay time determined by the value
in Entry Timer 2 on page 204. After entry time has expired, the system will activate into alarm
condition.
If a Delay-2 zone has not restored at the time the system is disarmed, a zone restore report will
be automatically sent to the receiving party.
Reserved
Reserved
24 Hour Medical
A 24 Hour Medical zone (Contact ID Event Code 100) is always ready to trigger the dialler,
horn speaker, bell and strobe regardless of whether the system is in the armed or disarmed
state. A medical report will be transmitted to the base station receiver. A 24 Hour Medical
zone will not send a restore report until the zone actually restores.
24 Hour Panic
A 24 Hour Panic zone (Contact ID Event Code 120) is always ready to trigger the dialler, horn
speaker, bell and strobe regardless of whether the system is in the armed or disarmed state. A
panic report will be transmitted to the base station receiver. A 24 Hour Panic zone will not
send a restore report until the zone actually restores.
24 Hour Hold-Up
A 24 Hour Hold-Up zone (Contact ID Event Code 122) is always ready to trigger the dialler,
horn speaker, bell and strobe regardless of whether the system is in the armed or disarmed
state. If you require the hold-up alarm to be silent, enable Option 4 – Silent Alarm in Zone
Options 1 on page 167. A 24 Hour Hold-Up zone will not send a restore report until the zone
actually restores.
24 Hour Tamper
A 24 Hour Tamper zone (Contact ID Event Code 137) is always ready to trigger the dialler,
horn speaker, bell and strobe regardless of whether the system is in the armed or disarmed
state. A 24 Hour Tamper zone will not send a restore report until the zone actually restores.
Reserved
Electronics Design and Manufacturing Pty Limited
ISSUE130
Summary of Contents for Solution 862
Page 1: ...Solution 862 Installation Manual ISSUE 1 30...
Page 2: ......
Page 4: ......
Page 6: ......
Page 74: ...74 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 118: ...118 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 149: ...User Codes This section includes the following Installer Code User Codes User Code Priority...
Page 154: ...154 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 188: ...188 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 212: ...212 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 228: ...228 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 240: ...240 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 245: ...Programming Sheets...
Page 254: ...254 Solution 862 Installation Manual ISSUE130 Electronics Design and Manufacturing Pty Limited...
Page 255: ...Index...
Page 262: ......