Charging system
–
battery
Warning
To check operation of the battery charging system, use the DDS, please refer to "
" (Sect. D 5).
Absolute value of voltage measured across the terminals of two of the three yellow cables (measured value will be the
same whichever the combination) must be within the range indicated in the table below.
(Ambient temperature:
20 °
C)
Caution
Disconnect generator cables from the electric system when the ignition key is positioned to OFF before testing.
Engine rpm
2000
6000
effective
V
27
±
10
78
±
10
Values notably lower than the mentioned values can be due to:
partially demagnetized rotor;
short-circuited coil windings.
In the above cases the whole generator assembly (rotor and stator) should be replaced.
If checks have a favourable outcome, reconnect generator to regulator with ignition key on OFF. Make sure that no
cables are damaged or disconnected.
Removing the generator
Disconnect the generator-side electrical cables (see diagram in "
Arrangement of wiring on frame
", Sect. P 1).
Remove generator cover, stator (A) and rotor (B) (Sect. N 8,