Description
#
Description
B
RS232
I
Print Head 1
C
Encoder 2
J
I/O Terminal Block 1
D
Print Head 2
K
Print Head 3
E
Print Head 4
L
I/O Terminal Block 2
F
Ethernet
M
Power Supply Input
G
USB
-
Electrical connections are prepared outside of the controller. Cables are passed through a
protective cover into the controller and are sealed. This allows the controller's IP rating to be
maintained.
To maintain the IP rating, use the solid grommets to block holes in the seal that are not needed.
For easy access to the controller's USB sockets, it is recommended to connect a USB extension
cable to the controller through the protective cover and seal.
Required tools: 2.5 mm and 4 mm hex keys.
To make electrical connections to the Gx-IC10 Controller:
1. Remove the protective cover and seal.
Gx-IC10 Cover and Seal
2. Put a grommet from the seal on each of the cables.
INSTALLATION
EPT053091 - Issue 5 - 07 May 2021
32
Summary of Contents for Gx-OEM
Page 1: ...Gx Series Product Manual Gx150i Gx350i Gx OEM ...
Page 63: ...3 Install the faceplate End of procedure INSTALLATION EPT053091 Issue 5 07 May 2021 58 ...
Page 65: ...3 Install the faceplate End of procedure INSTALLATION EPT053091 Issue 5 07 May 2021 60 ...
Page 122: ...The illustration below shows the Setup screen OPERATION 117 EPT053091 Issue 5 07 May 2021 ...
Page 197: ...EPT053091 Issue 5 07 May 2021 192 ...