No.
Alert Text
Alert Level
Description
6075
Check config file, groups
number locked
Alarm
(Red Alert)
There are more print groups configured
than enabled by the activation code.
Remedial action: Correct the number of
print groups in the configuration file.
6104
File
n
missing
Alarm
(Red Alert)
Cannot find the file.
Remedial action: Check the file. Copy
the file onto the system.
6111
Modify print label; not
enough memory
Alarm
(Red Alert)
Cannot load the label to print. Label file
is too big.
Remedial action: Reduce the number of
label elements and reduce the size of the
label.
6114
Faulty group number
Alarm
(Red Alert)
Error loading the label to print.
Remedial action: Check the print group
number. Correct the number and load
the label again.
6115
Fault print message field
Alarm
(Red Alert)
Error in the label.
Remedial action: Check elements in the
label and load the label again or restart
the controller.
6116
True type font error
Alarm
(Red Alert)
Error in label.
Remedial action: Check the font in the
label and restart the controller.
6118
Faulty print head number
Alarm
(Red Alert)
Error in label.
Remedial action: Check the print head
number. Correct the number and load
the label again.
6120
Error with bmp file
Alarm
(Red Alert)
Error in label.
Remedial action: Check the label's
graphic elements.
6121
Error in bmp file format
Alarm
(Red Alert)
Error in label.
Remedial action: Replace the incorrect
format graphic with correct format
graphic. Load the label again.
OPERATION
181
EPT053091 - Issue 5 - 07 May 2021
Summary of Contents for Gx-OEM
Page 1: ...Gx Series Product Manual Gx150i Gx350i Gx OEM ...
Page 63: ...3 Install the faceplate End of procedure INSTALLATION EPT053091 Issue 5 07 May 2021 58 ...
Page 65: ...3 Install the faceplate End of procedure INSTALLATION EPT053091 Issue 5 07 May 2021 60 ...
Page 122: ...The illustration below shows the Setup screen OPERATION 117 EPT053091 Issue 5 07 May 2021 ...
Page 197: ...EPT053091 Issue 5 07 May 2021 192 ...