4. REMOTE OPERATION
Page 135
© 1998-2008 DH Instruments, a Fluke Company
COMMAND
DESCRIPTION
*OPT?
Read the PG7000 options installed
PCTx(=)
Set or read the source for the piston-cylinder temp
PGEN(=)
Set or read the automated pressure generation setting
PISTONRDYx(=)
Set or read piston rotation rate limits.
PISTONVARx(=)
Set or read additional piston variables
PISTONx(=)
Set or read the piston header information
PISTON(=)
Set or read the piston in use
PPC=
Send a command to an external pressure generation/control component.
PPCPR
Read the pressure measured by a PPC pressure controller connected to PG7000’s
COM3.
PPOS
Read the current piston position
PRTPC
Set or read the piston cylinder temperature PRT information
PR
Read the current PG7000 defined pressure and “ready” status
PS=
Specify a new PG7000 target pressure, loading masses if AMH enabled
READYx(=)
Set or read the ready criteria for a specific “Setup”
READYCK(=)
Set or read the ready check flag status
REMOTE
Set the PG7000 into local lockout condition
RESET
Set basic PG7000 operating conditions to default. Equivalent to front panel “Reset,
Sets”.
RESUME
Resume the suspended process of setting a new pressure by remote command.
RESUME(=mode)
Set the resume mode, which determines whether a pressure setting process
initiated by remote command will pause after target entry and require the RESUME
comand to continue .
RPM(x)
Send a command to an external
DHI
RPM connected to COM2
*RST
Reset user settings to factory defaults
SETUP(=)
Set or read the setup to use
SN
Read the PG7000 serial number
SPEED
Read the piston rotation speed
*SRE(?)
Read or set the Service Request Register
*STB?
Read the Status Byte
TIME(=)
Set or read the current time
*TST?
Read the system self test results
UCOEF
Read the current pressure units conversion coefficient
UDD(=)
Set or read the user defined external barometer settings
UDU(=)
Set or read the user defined pressure unit
UDV(=)
Set or read the user defined external vacuum gage settings
UL(=)
Set or read the upper limit of an external pressure generation/control component.
UNIT(=)
Set or read the current pressure unit
VACPx(=)
Set or read the source for the vacuum measurement
VAC(=)
Set or read the vacuum reference flag
VENT(=)
To vent the test pressure to atmosphere if an automated pressure
generation/control component is being used for automatic pressure generation.
VER
Read version number of the internal software
VOL(=)
Read or set the currently active test volume for AutoGen using PG7203 or PG7307
with a PPCH pressure controller
#
Send a command through PG7000 to an external RPM on COM2