9 Application Instructions API 150-199
DVP-PLC Application Manual
9-85
K0
D214
M1029
DCIMR
Y0
END
K0
D210
DCIMR
Y0
K0
D206
DCIMR
Y0
K0
D202
DCIMR
Y0
= D0 K1
= D0 K2
= D0 K4
M0
K1
D0
D0
M0
M1029
3. Motion
explanation:
When PLC RUN and M0 = On, PLC will start the drawing of the first segment of the arc. D0 will plus 1 whenever a
segment of arc is completed and the second segment of the arc will start to execute automatically. The same
motion will keep executing until the fourth segment of arc is completed.