2 Functions of Devices in DVP-PLC
DVP-PLC Application Manual
2-5
Type
Device
Item
Range
Function
Frequency
measurement card
interruption
I180, 1 point
K Decimal
form
K-32,768 ~ K32,767 (16-bit operation)
K-2,147,483,648 ~ K2,147,483,647 (32-bit operation)
Const
a
nt
H Hexadecimal
form
H0000 ~ HFFFF (16-bit operation)
H00000000 ~ HFFFFFFFF (32-bit operation)
*1. Non-latched area cannot be modified.
*2. The preset non-latched area can be modified into latched area by setting up parameters.
*3. The preset latched area can be modified into non-latched area by setting up parameters.
*4. The fixed latched area cannot be modified
Latched settings for all devices in EH/EH2/SV series MPU:
*1: K-1 refers to the default setting is non-latched.
Power On/Off or the MPU switches between RUN/STOP:
Memory of ES/EX/SS V5.5 (and above)
Memory type
Power
Off
→
On
STOP
→
RUN
RUN
→
STOP
Clear all non-latched
areas (M1031)
Clear all latched
areas (M1032)
Default
setting
Clear when M1033 = Off
Non-latched Clear
Remain unchanged when M1033 = On
Clear Unchanged
0
Latched Unchanged
Unchanged
Clear
Unchanged
Special M,
Special D,
index register
Initial Unchanged
Unchanged
Initial
setting
Memory of SA/SX/SC/EH/EH2/SV series MPU:
General purpose
Latched
Special auxiliary relay
Latched
M0 ~ M499
M500 ~ M999
M1000 ~ M1999
M2000 ~ M4095
M
(Auxiliary relay)
Start: D1200 (K500)
End: D1201 (K999)
Some are latched and
cannot be modified.
Start: D1202 (K2,000)
End: D1203 (K4,095)
100 ms
10 ms
10 ms
1 ms
100 ms
T0 ~ T199
T200 ~ T239
T240 ~ T245
T246 ~ T249
T250 ~ T255
Default: non-latched
Default: non-latched
T
(Timer)
Start: D1204 (K-1)*1
End: D1205 (K-1)*1
Start: D1206 (K-1)*1
End: D1207 (K-1)*1
Accumulative type
It is fixed to be latched.
16-bit counting up
32-bit counting up/down
32-bit high-speed counting up/down
C0 ~ C99
C100 ~ C199
C200 ~ C219
C220 ~ C234
C235 ~ C245
C246 ~ C255
Default:
non-latched
Default: latched
Default:
non-latched
Default: latched
Default: latched
C
(Counter)
Start: D1208 (K100)
End: D1209 (K199)
Start: D1210 (K220)
End: D1211 (K234)
Start: D1212 (K235)
End: D1213 (K255)
Initial Zero
return
General
purpose
Latched Step
alarm
S0 ~ S9
S10 ~ S19
S20 ~ S499
S500 ~ S899
S900 ~ S1023
Non-latched (default)
Latched (default)
S
(Step relay)
Start: D1214 (K500)
End: D1215 (K899)
It is fixed to be latched.
General purpose
Latched
Special register
Latched
D0 ~ D199
D200 ~ D999
D1000 ~ D1999
D2000 ~ D9999
Default: non-latched
Default: latched
Default: latched
D
(Register)
Start: D1216 (K200)
End: D1217 (K999)
Some is latched and
cannot be modified.
Start: D1218 (K2,000)
End: D1219 (K9,999)
K0 ~ K9,999
File register
It is fixed to be latched.
Summary of Contents for DVP-PLC
Page 1: ...PLC PLC...
Page 28: ...1 Basic Principles of PLC Ladder Diagram DVP PLC Application Manual 1 24 MEMO...
Page 192: ...4 Step Ladder Instructions DVP PLC Application Manual 4 22 MEMO...
Page 472: ...8 Application Instructions API 100 149 DVP PLC Application Manual 8 70 MEMO...
Page 574: ...9 Application Instructions API 150 199 DVP PLC Application Manual 9 102 MEMO...