2 Functions of Devices in DVP-PLC
DVP-PLC Application Manual
2-87
No.
Function
M1133
Output switch for special high-speed pulse Y0 (50KHz) (On = enabled)
M1134
On = Continuous output switch for special high-speed pulse Y0 (50KHz)
M1135
“Number of pulses reached” flag for special high-speed pulse Y0 (50KHz)
D1133
Start No. of control register (D) for special high-speed pulse Y0 (50KHz)
2.
Parameters for D1133:
Index
Function
+ 0
The lower 16 bits of the 32 bits for output frequency of special high-speed pulse Y0
+ 1
The higher 16 bits of the 32 bits for output frequency of special high-speed pulse Y0
+ 2
The lower 16 bits of the 32 bits for number of output pulses of special high-speed pulse Y0
+ 3
The higher 16 bits of the 32 bits for number of output pulses of special high-speed pulse Y0
+ 4
The lower 16 bits of the 32 bits of the present number of special high-speed pulses Y0
+ 5
The higher 16 bits of the 32 bits of the present number of special high-speed pulses Y0
3. The
function:
All output frequency and number of pulses stated in the table above can be modified when M1133 = On and
M1135 = On. The modification will not affect the present output pulses. The present number of output pulses is
updated in every scan time. When M1133 turns from “Off” to “on”, the number will be cleared as “0”. When 1133
turns from “On” to “Off”, the last numner of output pulses will be shown.
Note:
The special high-speed pulse output function can only be used on specific Y0 output point when PLC is in RUN status.
It can coexist with PLSY (Y0) in the program and PLSY (Y1) will not be affected. If PLSY (Y0) instruction is executed
prior to this function, the function cannot be used and vice versa. When the function is executed, the general function,
general Y0 output will be invalid but Y1 ~ Y7 can be used.
The output frequency of this function is higher (max. 50KHz) than that of PLSY instruction.
Function Group
2-axis Synchronous Control (PH)
Number
M1133, M1135, D1133 ~ D1136
Contents:
1.
Special D and special M for 2-axis synchronous drawing oblique and arc for SC_V1.4 and versions above:
Device No.
Function
M1133
Start flag for Y10 output for two-axis synchronous control
M1135
Start flag for Y11 output for two-axis synchronous control
D1133
Start No. of control register (D) for Y10 output for two-axis synchronous control
D1134
Number of sections for Y10 output for two-axis synchronous control
D1135
Start No. of control register (D) for Y11 output for two-axis synchronous control
D1136
Number of sections for Y11 output for two-axis synchronous control
2.
Parameters for D1133, D1135:
Summary of Contents for DVP-PLC
Page 1: ...PLC PLC...
Page 28: ...1 Basic Principles of PLC Ladder Diagram DVP PLC Application Manual 1 24 MEMO...
Page 192: ...4 Step Ladder Instructions DVP PLC Application Manual 4 22 MEMO...
Page 472: ...8 Application Instructions API 100 149 DVP PLC Application Manual 8 70 MEMO...
Page 574: ...9 Application Instructions API 150 199 DVP PLC Application Manual 9 102 MEMO...