6 Application Instructions API 00-49
DVP-PLC Application Manual
6-16
FOR
K3
FOR
K4
NEXT
NEXT
A
B
Program Example 2:
When X7 = Off, PLC will execute the program between FOR ~ NEXT. When X7 = On, CJ instruction jumps to P6 and
avoids executing the programs between FOR ~ NEXT.
X7
M0
M0
P6
MOV
FOR
MOV
D0
D0
K3
K0
Y10
INC
MEXT
X10
D0
D1
CJ
P6
Summary of Contents for DVP-PLC