6 Application Instructions API 00-49
DVP-PLC Application Manual
6-24
API Mnemonic
Operands
Function
15
BMOV P
Block Move
Controllers
ES/EX/SS SA/SX/SC EH/SV
Bit Devices
Word Devices
Program Steps
Type
OP
X Y M S K H
KnX
KnY
KnM KnS T C D E F
S
*
*
*
*
*
*
*
D
*
*
*
*
*
*
n
*
*
*
*
*
BMOV, BMOVP: 7 steps
PULSE 16-bit 32-bit
ES EX SS SA SX SC EH SV ES EX SS SA SX SC EH SV ES EX SS SA SX SC EH SV
Operands:
S
: Start of source devices
D
: Start of destination devices
n
: Number of data to be moved
Explanations:
1. Range
of
n
: 1 ~ 512
2.
See the specifications of each model for their range of use.
3.
The contents in n registers starting from the device designated by
S
will be moved to n registers starting from
the device designated by
D
. If n exceeds the actual number of available source devices, only the devices that
fall within the valid range will be used.
Program Example 1:
When X10 = On, the contents in registers D0 ~ D3 will be moved to the 4 registers D20 ~ D23.
X10
D20
K4
D0
D1
D2
D3
D20
D21
D22
D23
n=4
Program Example 2:
1.
Assume the bit devices KnX, KnY, KnM and KnS are designated for moving, the number of digits of
S
and
D
has
to be the same, i.e. their n has to be the same.
2.
ES/EX/SS do not support the use of KnX, KnY, KnM, KnS and E, F index register modification.
M1000
K1M0
K1Y0
K3
M0
M1
M2
M3
M4
M5
M6
M7
M8
M9
M10
n=3
M11
Y10
Y11
Y12
Y13
Summary of Contents for DVP-PLC
Page 1: ...PLC PLC...
Page 28: ...1 Basic Principles of PLC Ladder Diagram DVP PLC Application Manual 1 24 MEMO...
Page 192: ...4 Step Ladder Instructions DVP PLC Application Manual 4 22 MEMO...
Page 472: ...8 Application Instructions API 100 149 DVP PLC Application Manual 8 70 MEMO...
Page 574: ...9 Application Instructions API 150 199 DVP PLC Application Manual 9 102 MEMO...