9 Application Instructions API 150-199
DVP-PLC Application Manual
9-28
M1335
:
For EH, CH1 pulse output pauses.
For EH2/SV, CH1 pulse output stops.
M1336
:
For EH/EH2/SV, “CH0 sends out pulses” indication.
M1337
:
For EH/EH2/SV, “CH1 sends out pulses” indication.
M1520
:
For EH2/SV, CH2 pulse output stops.
M1521
:
For EH2/SV, CH3 pulse output stops.
M1522
:
For EH2/SV, “CH2 sends out pulses” indication.
M1523
:
For EH2/SV, “CH3 sends out pulses” indication.
M1534
:
For EH2/SV, designated deceleration time of CH0 (should be used with D1348).
M1535
:
For EH2/SV, designated deceleration time of CH1 (should be used with D1349).
M1536
:
For EH2/SV, designated deceleration time of CH2 (should be used with D1350).
M1537
:
For EH2/SV, designated deceleration time of CH3 (should be used with D1351).
M1532
:
For EH2/SV, direction signal of CH2.
M1533
:
For EH2/SV, direction signal of CH3.
6.
Special registers for EH/EH2/SV series MPU:
D1220
:
For EH/EH2/SV, phase setting of CH0 (Y0, Y1): D1220 determines the phase by the last two
bits; other bits are invalid.
1.
K0: Y0 output
2.
K1: Y0, Y1 AB-phase output; A ahead of B.
3.
K2: Y0, Y1 AB-phase output; B ahead of A.
4.
K3: Y1 output
D1221
:
For EH/EH2/SV, phase setting of CH1 (Y2, Y3): D1221 determines the phase by the last two
bits; other bits are invalid.
1. K0: Y2 output
2. K1: Y2, Y3 AB-phase output; A ahead of B.
3. K2: Y2, Y3 AB-phase output; B ahead of A.
4. K3: Y3 output
D1222
:
For EH/EH2/SV, the time difference between the direction signal and pulse output sent by
CH0.
D1223
:
For EH/EH2/SV, the time difference between the direction signal and pulse output sent by
CH1.
D1229
:
For EH2/SV, phase setting of CH2 (Y4, Y5): D1229 determines the phase by the last two bits;
other bits are invalid.
1. K0:
Y4
output
2. K1: Y4, Y5 AB-phase output; A ahead of B.
3. K2: Y4, Y5 AB-phase output; B ahead of A.
4. K3:
Y5
output
D1230
:
For EH2/SV, phase setting of CH3 (Y6, Y7): D1230 determines the phase by the last two bits;
other bits are invalid.
1. K0:
Y6
output
2. K1: Y6, Y7 AB-phase output; A ahead of B.
3. K2: Y6, Y7 AB-phase output; B ahead of A.
4. K3:
Y7
output
Summary of Contents for DVP-PLC
Page 1: ...PLC PLC...
Page 28: ...1 Basic Principles of PLC Ladder Diagram DVP PLC Application Manual 1 24 MEMO...
Page 192: ...4 Step Ladder Instructions DVP PLC Application Manual 4 22 MEMO...
Page 472: ...8 Application Instructions API 100 149 DVP PLC Application Manual 8 70 MEMO...
Page 574: ...9 Application Instructions API 150 199 DVP PLC Application Manual 9 102 MEMO...