9 Application Instructions API 150-199
DVP-PLC Application Manual
9-86
API Mnemonic
Operands
Function
194
D CIMA
2-Axis Absolute Position Arc
Interpolation
Controllers
ES/EX/SS SA/SX/SC EH/SV
Bit Devices
Word Devices
Program Steps
Type
OP
X Y M S K H
KnX
KnY KnM KnS T
C
D
E
F
S
1
*
*
*
S
2
*
*
*
S
*
D
*
DCIMA: 17 steps
PULSE 16-bit 32-bit
ES EX SS SA SX SC EH SV ES EX SS SA SX SC EH SV ES EX SS SA SX SC EH SV
Operands:
S
1
: Number of output pulses of X axis
S
2
: Number of output pulses of Y axis
S
: Parameter setting
D
: Pulse
output device
Explanations:
1. Flags: M1029, M1030, M1334, M1335. See remarks of API 191 DPPMR for more details.
2. This instruction only supports EH2/SV series MPU, not EH series. In terms of pulse output methods, this
instructin only supports “pulse + direction” mode.
3.
S
1
and
S
2
are the designated (absolute designation) number of output pulses in X axis (Y0 or Y4) and Y axis (Y2
or Y6). The range of the number is -2,147,483,648 ~ +2,147,483,647. When
S
1
and
S
2
are larger than pulse
present value registers CH0 (D1337 high word, D1336 low word), CH1 (D1339 high word, D1338 low word), CH2
(D1376 high word, D1375 low word), and CH3 (D1378 high word, D1377 low word), the output direction will be
positive and direction signals Y1, Y3, Y5, Y7 will be On. When
S
1
and
S
2
are less than pulse present value
registers, the output direction will be negative and direction signals Y1, Y3, Y5, Y7 will be Off.
4. The lower 16 bits of
S
(settings of direction and resolution): K0 refers to clockwise 10-segment (average
resolution) output; K2 refers to clockwise 20-segment (higher resolution) output and a 90
°
arc can be drawn (see
figure 1 and 2). K1 refers to counterclockwise 10-segment (average resolution) output; K3 refers to
counterclockwise 20-segment (higher resolution) output and a 90
°
arc can be drawn (see figure 3 and 4).
5. The higher 16 bits of
S
(settings of motion time): K0 refers to 0.1 second. The setting range for average resolution
is K1 ~ K100 (0.1 sec. ~ 10 secs.), for higher resolution is K2 ~ K200 (0.2 sec. ~ 20 secs.) This instruction is
restricted by the maximum pulse output frequency; therefore when the set time goes faster than the actual output
time, the set time will be automatically modified.
(0, 0)
X
Y
(S , S )
1
2
1
0
s
e
g
m
e
n
ts
10 se gment s
F igur e 1
(0, 0)
X
Y
(S , S )
1
2
2
0
s
e
g
m
e
n
ts
20 se gment s
F igur e 2
Summary of Contents for DVP-PLC
Page 1: ...PLC PLC...
Page 28: ...1 Basic Principles of PLC Ladder Diagram DVP PLC Application Manual 1 24 MEMO...
Page 192: ...4 Step Ladder Instructions DVP PLC Application Manual 4 22 MEMO...
Page 472: ...8 Application Instructions API 100 149 DVP PLC Application Manual 8 70 MEMO...
Page 574: ...9 Application Instructions API 150 199 DVP PLC Application Manual 9 102 MEMO...