7 Application Instructions API 50-99
D V P - P L C A P P L I C AT I O N M A N U A L
7-62
2. Key in numbers:
0 1
2 3 4 5 6 7 8 9
D0
10
3
10
2
10
1
10
0
number key
1-digit BCD code
BCD value
BCD value
BIN value
overflow
3. Function keys input:
a) When A is pressed, M0 will be On and retained. When
D is pressed next, M0 will be Off, M3 will be On and
retained.
b) When many keys are pressed at the same time, the
first key pressed has the priority.
F
E
D
C
B
A
M5
M4
M3
M2
M1
M0
4. Key output signal:
a) When any of A ~ F is pressed, M6 will be On for once.
b) When any of 0 ~ 9 is pressed, M7 will be On for once.
5. When X4 goes Off, the keyed-in value prior to D0 will remain unchanged, but M0 ~ M7 will all be Off.
6. External
wiring:
Y13
Y12
Y11
Y10
C
X13
X12
X11
X10
S/S
C
D
E
F
8
9
A
B
4
5
6
7
0
1
2
3
PLC (transistor output)
+24V
24G