C h a p t e r 1 2 Tr o u b l e s h o o t i n g
1 2 - 9
Error
code
Description
Remedy
16#2000
There is no END in the program
in the PLC. (SM5)
1. Compile the program again, and download the program
again.
2. Reinstall ISPSoft, compile the program again, and
download the program again.
16#2001
Syntax error (SM5)
Check the program, compile the program again, and
download the program again.
16#2002
GOEND is used incorrectly.
(SM5)
Check the program, compile the program again, and
download the program again.
16#2003
The devices used in the program
exceed the range. (SM0/SM5)
Check the program, compile the program again, and
download the program again.
16#2004
The part of the program specified
by the label used in CJ/JMP is
incorrect, or the label is used
repeatedly. (SM0/SM5)
Check the program, compile the program again, and
download the program again.
16#2005
The N value used in MC is not
the same as the corresponding N
value used in MCR, or the
number of N values used in MC
is not the same as the number of
N values used in MCR. (SM5)
Check the program, compile the program again, and
download the program again.
16#2006
The N values used in MC do not
start from 0, or the N values used
in MC are not continuous. (SM5)
Check the program, compile the program again, and
download the program again.
16#2007
The operands used in ZRST are
not used properly. (SM5)
Check the program, compile the program again, and
download the program again.
16#200A
Invalid instruction (SM5)
Check the program, compile the program again, and
download the program again.
16#200B
The operand
n
or the other
constant operands exceed the
range. (SM0/SM5)
Check the program, compile the program again, and
download the program again.
16#200C
The operands overlap.
(SM0/SM5)
Check the program, compile the program again, and
download the program again.
16#200D
An error occurs when the binary
number is converted into the
binary-coded decimal number.
(SM0/SM5)
Check the program, compile the program again, and
download the program again.
16#200E
The string does not end with
0x00. (SM0/SM5)
Check the program, compile the program again, and
download the program again.
16#200F
The instruction does not support
the modification by an index
register. (SM5)
Check the program, compile the program again, and
download the program again.
16#2010
1. The instruction does not
support the device.
2. Encoding error
3. The instruction is a 16-bit
instruction, but the constant
operand is a 32-bit code.
(SM5)
Check the program, compile the program again, and
download the program again.
16#2011
The number of operands is
incorrect. (SM5)
Check the program, compile the program again, and
download the program again.
16#2012
Incorrect division operation
(SM0/SM5).
Check the program, compile the program again, and
download the program again.
Summary of Contents for AH500 series
Page 35: ...AH500 Hardware and Operation Manual 2 2 2 12 2 Profiles 2 117 2 12 3 Dimensions 2 118 ...
Page 153: ...AH500 Hardware and Operation Manual 2 120 MEMO ...
Page 167: ...AH500 Hardware and Operation Manual 3 14 MEMO ...
Page 343: ...AH500 Hardware and Operation Manual 6 38 MEMO ...
Page 361: ...AH500 Hardware and Operation Manual 7 18 MEMO ...
Page 403: ...Chapter 8 Hardware Configuration 8 42 MEMO ...
Page 412: ...Chapter 9 Network Configuration 9 9 ...
Page 445: ...AH500 Hardware and Operation Manual 9 42 MEMO ...
Page 552: ...Chapter 12 Troubleshooting 12 3 12 1 3 Troubleshooting Procedure ...
Page 649: ...AH500 Hardware and Operation Manual A 8 ...
Page 657: ...AH500 Hardware and Operation Manual A 16 MEMO ...
Page 658: ...B 1 Appendix B Device Addresses Table of Contents B 1 Device Addresses B 2 ...
Page 663: ...AH500 Hardware and Operation Manual C 4 MEMO ...
Page 681: ...AH500 Hardware and Operation Manual 3 14 MEMO ...