Completion of reading: The master station finishes reading data form a slave station
Completion of writing: The master station finishes writing data into a slave station.
Additional remark:
If the reading of data and the writing of data are synchronous, the related flags will be controlled in the
ways described below.
Read error
Write error
Completion
of reading
Completion
of writing
The master station stops reading
data and writing data
simultaneously, or the master
station is reading data and writing
data simultaneously.
OFF
OFF
OFF
OFF
The master station finishes reading
data and writing data
simultaneously.
OFF
OFF
ON
ON
Timeout
ON
ON
OFF
OFF
The master station can not produce
a packet which will be sent.
ON
ON
OFF
OFF
The data sent by a slave station can
not be stored in the master station.
ON
OFF
OFF
ON
3. Description of the setting of the parameters related to a PLC Link:
The setting of the parameters related to a PLC Link is described below. (Suppose the master station and
slave station 1 are AHCPU530-EN.) The data in the device addresses starting from D100 in slave station 1
is read into the device address starting from D9 in the master station. The number of data read from slave
station 1 is 10. The data in the device addresses starting from Y0.0 in the master station is written into the
device addresses starting from Y2.0 in slave station 1. The number of written into slave station 1 is 5. The
slave station type is AHCPU530-EN (16#E001). The slave station address is 16#0001.
Item
Reading/Writing
Device code
Value
Start address in the
master station
Reading
SR1404
16#0000
SR1405
16#0009
Writing
SR1468
16#0000
SR1469
16#A000
Start address in slave
station 1
Reading
SR1532
16#0000
SR1533
16#0064
Writing
SR1596
16#0000
SR1597
16#A020
Number of data read
from slave station 1
Reading
SR1660
16#000A
Number of data
written into slave
station 1
Writing
SR1692
16#0005
Slave station type
Reading
SR1724
16#E001
Writing
Slave station address
Reading
SR1756
16#0001
Writing
Device type
Reading
SR1340
16#0000
Writing
SR1372
16#0001
Additional remark:
There are a variety of Delta PLCs. Users can construct a PLC Link by connecting AH500 series CPU
modules to DVP series PLCs, and other models. Consequently, there are limitations on the devices which
can be used, the data exchange which can be performed, and the number of data which can be
exchanged.
Summary of Contents for AH500 series
Page 35: ...AH500 Hardware and Operation Manual 2 2 2 12 2 Profiles 2 117 2 12 3 Dimensions 2 118 ...
Page 153: ...AH500 Hardware and Operation Manual 2 120 MEMO ...
Page 167: ...AH500 Hardware and Operation Manual 3 14 MEMO ...
Page 343: ...AH500 Hardware and Operation Manual 6 38 MEMO ...
Page 361: ...AH500 Hardware and Operation Manual 7 18 MEMO ...
Page 403: ...Chapter 8 Hardware Configuration 8 42 MEMO ...
Page 412: ...Chapter 9 Network Configuration 9 9 ...
Page 445: ...AH500 Hardware and Operation Manual 9 42 MEMO ...
Page 552: ...Chapter 12 Troubleshooting 12 3 12 1 3 Troubleshooting Procedure ...
Page 649: ...AH500 Hardware and Operation Manual A 8 ...
Page 657: ...AH500 Hardware and Operation Manual A 16 MEMO ...
Page 658: ...B 1 Appendix B Device Addresses Table of Contents B 1 Device Addresses B 2 ...
Page 663: ...AH500 Hardware and Operation Manual C 4 MEMO ...
Page 681: ...AH500 Hardware and Operation Manual 3 14 MEMO ...