42
COMMUNICATOR CODES
LOCATION
PAGE
DESCRIPTION
DATA
"DEFAULT"
133
12
NUMBER OF DIAL ATTEMPTS
‘6’ SIX
134
12
PRIMARY ENTRY DELAY TIME
'3'30 SECONDS
13S
i2
PHIMARY EXIT DELAY (10 SEC INCREMENTS)
‘6’60 SECONDS
1a6
12
SECONDARY ENTRY DELAY (10 SEC INCREMENTS)
'3'30 SECONDS
137
12
SECONDARY EXIT DELAY (10 SEC INCREMENTS
'6' 60SECONDS
136
12
SIREN CUTOFF TIME (2 MINUTE INCREMENTS)
'4 '8 MINUTES
139
13
ZONE#1- ZONE TYPE
LOCATIONS 139-154
'3'
ENTRY/EXIT
140
13
ZONE#2- ZONE TYPE
DATA
ZONE TYPES
141
13
ZONE #3- ZONE TYPE
1
Day Zone
142
13
ZONE#4- ZONE TYPE
2
24 Hour
V INSTANT
143
13
ZONE #5- ZONE TYPE
3
Entry/Exit
'6' INSTANT
144
13
ZONE #6- ZONE TYPE
4
Interior Delay
'6'INSTANT
145
13
ZONE#7- ZONE TYPE
5
Interior Follower
V INSTANT
146
13
ZONE#8- ZONE TYPE
6
Instant
'6' INSTANT
147
13
ZONE #9- ZONE TYPE
7
Secondary Delay
'6' INSTANT
148
13
ZONE#10-ZONE TYPE
8
Fire
'6' INSTANT
149
13
ZONE#11-ZONETYPE
9
Keyswitch
's' INSTANT
150
13
ZONE #12-ZONETYPE
'6' INSTANT
151
13
ZONE#13-ZONE TYPE
'6' INSTANT
152
13
ZONE#14-ZONE TYPE
'6' INSTANT '
153
13
ZONE#15-ZONE TYPE
V INSTANT
154
13
ZONE#16-ZONE TYPE
'6' INSTANT
155
14
ZONE#1- SPECIAL CHARACTERISTICS
'12'
156
14
ZONE.- SPECIAL CHARACTERISTICS
LOCATIONS 155-170
'12'
157
14
ZONE#3- SPECIAL
CHARACTERISTICS
VALUE
CHARACTERISTIC
'12'
158
14
ZONE#4- SPECIAL
CHARACTERISTICS
1
Fast Loop Response
(200mS)
‘12’
159
14
ZONE
MS-
SPECIAL
CHARACTERISTICS
2
Group Isolate Zone
'12'
160
14
ZONE#6- SPECIAL
CHARACTERISTICS
4
Entry-Guard Zone
'12'
161
14
ZONE#7- SPECIAL
CHARACTERISTICS
8
Zone Isolate
Capability
'12'
162
14
ZONE
a3-
SPECIAL CHARACTERISTICS
'12'
163
14
ZONE #9- SPECIAL CHARACTERISTICS
'12'
164
14
ZONE #10-SPECIALCHARACTERISTICS
'12'
165
14
ZONE #it-SPECIALCHARACTERISTICS
'12'
166
14
ZONE#12-SPECIAL CHARACTERISTICS
'12'
167
14
ZONE #13-SPECIALCHARACTERISTICS
'12'
166
14
ZONE #14-SPECIALCHARACTERISTICS
'12'
169
14
ZONE #15-SPECIALCHARAOTERISTICS
'12'
170
14
ZONE #16-SPECIALCHARACTERISTICS
'12'
FOR LOCATIONS 133 THRU 138, YOU PROGRAM A NUMBER BETWEEN “0” AND “15”