22
Location 240: Inverting Auxiliary Outputs And Setting Onboard Form C And Form A
Relay
Operation.
(
Form C Relay Tied To Pin #3 And Form A Relay Tied To Pin #4)
The auxiliary outputs of the DL-300E are normally POSITIVE (+) going NEGATIVE (-). They can be changed to a normally
NEGATIVE (-)going POSITIVE (+) by programming the appropriate number in this location. Auxiliary output 1 has a value
of "1 ", Auxiliary output 2 has a value of "2", Auxiliary output 3 has a value of "4", and Auxiliary output 4 has a value of
"8". The values for the outputs that you wish to change to NEGATIVE going POSITIVE must be added together and the
total programmed in this location. For example, if you wished to make outputs 2 (=2) and 3 (=4) NEGATIVE going
POSITIVE, you would program "6" (2+4=6) in this location. The output for pin 3 is automatically tied to the onboard form
C relay (Terminal locations 10, 11, & 12), and pin 4 is tied to the form A relay (Terminal locations 7 & 8). You should take
this into consideration when planning auxiliary output operation. If you need a relay output on pins 1 or 2 you must add a
relay that can be tripped with the voltage and current available at these pins. Making outputs 3 and 4 normally negative
going positive, will have the effect of making the relay attached to that pin normally pulled in, and drop out when the
output is activated. NOTE: THE PINS ARE CURRENT LIMITED TO 250 MICRO AMPS POSITIVE AND 20 mA NEGATIVE.
Location 241: Changing Timing Increments From Seconds To Minutes For Auxiliary
Outputs
The number programmed into this location will determine if the 4 auxiliary pins described in the above locations will
create 2 to 28 second, or 2 to 28 minute voltage trigger outputs. If this location contains a "0" (factory default ="0"),
the output duration time is computed in seconds. By adding the value that corresponds to each pin number in the
table below, and programming the sum in this location, the "second" increments.will convert to "minute" increments
for the pin(s) selected:
VALUE
NUMBERS
1
Pin #1
2
Pin #2
4
Pin #3
8
Pin #4
Example 1-
To change duration time from seconds to minuets Pin 1, program a "1" in this location.
Example 2 -
To change duration time from seconds to minutes for Pins 1 & 3, program a "5" (1 + 4 =
"5"),
Example 3 -
To change duration time from seconds to minutes for Pins 2 & 4, program a "10" (2 + 8 =
"10")
Location 242: Answerinq Machine
Defeat
Location 242 contains the answering machine defeat enable. To defeat an answering machine, two telephone calls must be
made to the premises. On the first call, let the phone ring the same number of times (or less) as the number programmed
in location 242 (maximum 3). The control panel will detect these rings and start a 45 second timer. If a call comes in
during that 45 second time frame, the control panel will answer on the first ring. To disable this feature, program a "0" in
this location.
Location 243: Number Of Rings To Answer
Download Call
Location 243 contains the number of rings the DL-300E must detect before answering the telephone when initiating a
download. If a number from "1" to "15" is programmed in this location, the control will answer after the number of rings
entered times 2 has been detected. If a "0" is programmed, the DL-300E will not answer the download call. (SEE
LOCATION 242: ANSWERING MACHINE DEFEAT)