Location 244: Assigning The Chime Enable Code
Program the one digit number that the end user will use to enable the
Chime
mode. This number can be any number 0
to 9. Factory default is "1 " and this feature is enabled. If you do not wish to enable the
Chime
feature at this
installation, program a "15" in this location. NOTE! This number should not be the same as the
Quick Arm
code.
Location 245: Assigning The Partial Mode Enable Code
Program the one digit number that the end user will use to activate the
Partial
Mode.
This number can be any number
1 to 9. Factory default is "0" and this feature is enabled. If you do not wish to enable the
Partial Mode
feature at this
installation, program a "15" in this location. NOTE! The first digit of this code should not match the Quick-Arm digit, or
the first digit of the
Chime
enable code. Location 220 must contain a "0" for
Partial
Mode
to work.
PROGRAMMING FOR PARTITIONS
Locations 247 through 249 are used to program the number of zones in partitions 1, 2, and 3, with the remaining zones
automatically assigned to the next numerical partition, which would be 4 if all three location are programmed. If only the
first location 247 has a number programmed in it, all remaining zones will automatically go to partition 2. You can
program any number of zones per partition up to a maximum of 15. All zones must be in numerical sequence. For
example, if you choose to have five zones in partition 1 and 11 zones in partition 2, you would program a 5 in location
247 and zones 1-5 would be assigned to partition 1, while zones 6 through 16 would be assigned to partition 2. You
cannot assign zones out of sequence such as placing zones 1-3-5-7-9 in partition 1 and 2-4-6-8 in partition two. Factory
default is no partitions enabled and all zones are assigned to partition 1 (the control) without restriction. Note: When
partitions are assigned in these locations, you may need to program locations 64-79, 124-131, 132, 213, 217, 224, 228,
232, 236, 246, and 572-586 which are sensitive to partitioning.
Location 246: Common Area Enable
If a "1" is programmed in location 246, Partition 1 will become a
Common Area
for all selected partitions. When
enabled, Partition 1 will automatically disarm when any other partition is disarmed, and will automatically arm when all
partitions have been armed. Care should be taken to allow sufficient entry delay time for Partition 1 to allow the user to
reach his designated partition code pad and enter a code. Exit delay time is the combination of the delay for the last
partition to arm and the delay entered for Partition 1. Factory default is "0" and this feature is disabled. NOTE: Partition
one (1) becomes the Common Area when enabled. In the factory default, the Common Area will not send open/closing
reports. To enable open/closing reports for the Common Area, program a "3" in this location.
Location 247: Number Of Zones In Partition 1
Factory default is "0", and the control is not partitioned. Thus all 16 (32 if expander is utilized) are assigned to the one
group. NOTE: When no partitions are enabled, all features or characteristics associated with partitions are contained
within one group.
Location 248: Number Of Zones In Partition 2
Factory default is "0", and Partition 2 is not enabled.
Location 249: Number Of Zones In Partition 3
Factory default is "0", and Partitions 3 and 4 are not enabled.