33
Location 428-443: Special Communicator Reporting Characteristics For Zones
17-32
Locations 428-443 are used to assign communicator characteristics to individual zones 17 through 32. Location 428 is
for zone
X17 and location 443 is for zone 32. Each zone can have one or a combination of these characteristics. Factory default
for all zones is "11" (1 + 2 + 8 ="11 "). This means that each zone has
RESTORE REPORTING (Value=1), ISOLATE
REPORTING
(Value=2), and REPORT CANCELING (Value=8
)
enabled. It should be noted that these locations are used to
enable individual zone report capability by zone. A reporting code must be programmed in the appropriate location to
enable overall reporting capability of Restore reports (location 364), Isolate reports (location 368), and Trouble/24 Hour
tamper reports (location 372).
VALUE
REPORTING CHARACTERISTICS
1
Restore Reporting
2
Isolate Reporting
4
Trouble/24 Hour Tamper Reporting
8
Report Canceling
Location 444-447: Programming the Communicator Code for
Zone 17
Locations 444-447 are used to control the communicator code for zone 17. Zone 17 is automatically enabled and when
contact
ID
is selected the default report is event "130 - Burglary" with point "17" when in alarm. Refer to appendix 1 if a
different event type is required. The defaults are "3:1:7:5" with telephone number 1 and the event log enabled
.
Location 448-451: Programming the Communicator Code for Zone 18
Locations 448-451 are used to control the communicator code for zone 18. Zone 18 is automatically enabled and when
contact
ID
is selected the default report is event "130 - Burglary" with point "18" when in alarm. Refer to appendix 1 if a
different event type is required. The defaults are "3:1:8:5" with telephone number 1 and the event log enabled.
Location 452-455: Programming the Communicator Code for Zone 19
Locations 452-455 are used to control the communicator code for zone 19. Zone 19 is automatically enabled and when
contact
ID
is selected the default report is event "130 - Burglary" with point "19" when in alarm. Refer to appendix 1 if a
different event type is required. The defaults are "3:1:9:5" with telephone number 1 and the event log enabled.
Location 456-459: Programming the Communicator Code for Zone 20
Locations 456-459 are used to control the communicator code for zone 20. Zone 20 is automatically enabled and when
contact ID is selected the default report is event "130 - Burglary" with point "20" when in alarm. Refer to appendix 1 if a
different event type is required. The defaults are "3:2:0:5" with telephone number 1 and the event log enabled.
Location 460-463: Programming the Communicator Code for Zone 21
Locations 460-463 are used to control the communicator code for zone 21. Zone 21 is automatically enabled and when
contact
ID
is selected the default report is event "130 - Burglary" with point "21" when in alarm. Refer to appendix 1 if a
different event type is required. The defaults are "3:2:1:5" with telephone number 1 and the event log enabled.