32
Location 396-411: Assigning Special Characteristics for Zones 17-32
Locations 396 through 411 are used to assign zone characteristics for zones 17 through 32. Location 396 is for zone
17 an location 411 is for zone 32. Each zone can have any or all of the following characteristics regardless of the
zone type select
in locations 380-395 excluding Fire zones, which cannot have isolate capability enabled. Factory default is "12" for
each of these locations, meaning that Zone Isolate Capability & Partial Mode are enabled, and the other
characteristics are not enabled. To include other characteristics, add their value, and program the sum in the
appropriate location. See the table below for zone
characteristics and their corresponding values.
VALUE
CHARACTERISTIC
1
Fast Loop Response
(200mS)
2
Group Isolate Zone
4
Partial Mode Zone
8
Zone Isolate
Capability
Example 1
-To add Group Isolate Zone (Value=2) to Zone Isolate Capability (Value=8) for zone 20 (location 399),
add
the value of the two characteristics (2 + 8--'10"), and program the sum of '10" in location 399.
Example 2
-To enable ALL characteristics for zone 20, add the value of all characteristics (1 + 2 + 4 + 8 = "15"),
and
program the sum of '15" in location 399 (zone 10 characteristics location).
Example 3-
To disable all characteristics and create a Non Isolatable Zone, program a '0' In the appropriate
location.
Location 412-427: Assigning Audible Characteristics For Zones 17-32
Locations
412-427 are used to assign the audible characteristics zones 17 through 32. Location 412 is for zone 17,
and location 427 is for zone 32. Each zone can be silent (SILENT
VALUE="0 ),
or have one, or a combination of the
following audible characteristics. To determine the appropriate data for these locations, refer to the chart below and
add the sum of the corresponding values to arrive at the correct data for these locations. Zones 17-32 have a factory
default setting of "13" (1+ 4 + 8 = "13"). This means that zones 17-32 will create a yelp siren output and a code
pad sounder output when an alarm is created. To select the audible characteristics for any zone, add the values of
the audible characteristics from the table below, and program the sum in the appropriate locations 412-427. NOTE:
If a Fire zone type is selected in locations 380-395, standard fire zone characteristics will override any selection made
for a zone in this section. If you wish for the zone to be SILENT, program a "0" in the appropriate location.
VALUE
AUDIBLE CHARACTERISTICS
1
Yelp Siren Audible
2
Steady Siren Audible
4
Code pad Sounder Audible
8
Chime Enable