Location 328-330: Code Pad Auxiliary 2 ([41 & !61) Communicator
Codes
The DL-300E has the ability to report an auxiliary 2 code and activate the pulsing buzzer each time the [4] and [6] keys
are pressed simultaneously on the Code Pad. The desired reporting code must be programmed into these locations.
When contact I.D is selected, program Data 1 with the required event code from appendix 1 to enable this report event.
Program a "11 " in Data 1 to report event "100 - Medical". If activated, the code pad sounder may be silenced by
entering any valid arm/disarm code. No restore code is reported for this event. If Data 1 is "0", the Auxiliary 2 double
caprice is disabled. The defaults are "0:0:0:5" with telephone number 1 and the event log enabled.
Location 332-334: code Pad Panic ([*] & !#1) Communicator Codes
The DL-300E has the ability to report a Code Pad panic code and activate the burglary siren (if not selected silent) each
time the [*] and [#] keys are pressed simultaneously on the Code Pad. The desired reporting code must be programmed
into these locations. When contact I.D is selected, program Data 1 with the required event code from appendix 1 to
enable this report event. Program a "2" in Data 1 to report event "120 - Code Pad Panic". If activated, the code pad
sounder may be silenced by entering any valid arm/disarm code. No restore code is reported for this event. If Data 1 is
"0", the Code pad panic double caprice is disabled. The defaults are "2:0:0:5" with Code pad panic communicator code,
telephone number 1 and the event log enabled.
Location 336-338:code Pad Tamper Communicator Codes
The DL-300E has the ability to lock out the Code Pad for 1 minute if 30 or more key presses are made without producing
a valid code. The desired communicator code must be programmed into these locations to enable this feature. When
contact I.D is selected, program a "1" in Data 1 to report event "137 - Code Pad Tamper". No restore code is reported
for this event. If Data 1 is "0", the Code Pad Tamper is disabled. The defaults are "1:0:0:5" with telephone number 1
and the event log enabled.
Location 340-342: Automatic Test Communicator Codes
The DL-300E has the ability to send autotest reports to the base station at weekly intervals or hourly intervals from 1 to
99 hours apart. The desired communicator code must be programmed into these locations. When contact I.D is selected,
program a "1" in Data 1 to report event "602 - Auto test". No restore code is reported for this event. If Data 1 is "0",
Auto Test is disabled. The defaults are "0:0:0:5" with telephone number 1 and the event log enabled.
Location344-347:Reserved
Location 348: Communicator Code To Report Openings
The DL-300E has the ability to report an opening code each time the control is disarmed. The desired opening code is
programmed in this location. If this location contains "0", openings will not be reported. When using contact I.D,
program a "1" in this location to enable reporting of system openings, the event code "401" will be reported. When using
the Quick-Arm digit, the user number is 29. When using a keyswitch, the user number is 30.
Location 349: Opening Phone Selector
If a phone number other than phone #1 is desired, I.E. for dual or split reporting. A binary number must be programmed
into this location. This is derived by adding a "1" for phone #1, a "2" for phone #2 and a "4" for the internal log. Factory
default is "5" which causes open/closing to report on phone #1 and internal log if the communicator event is enabled.