13
Location 133: Entering The Number Of Dial Attempts
Location 133 is used to enter the number of dial attempts (1 to 15 Attempts) the communicator will try for the appropriate phone
number(s) before ending the notification process. Factory default is "6" and the communicator will make 6 attempts to the first
number, and then 6 attempts to the second number, if a second number is programmed. If the factory default is modified in location
132, the first and second numbers will be called at a minimum the number times listed in this location, however this number might
double and the sequence might change according to the number programmed.
Location 134: Programming The Entry Delay Time
Location 134 contains the number of 10 second increments in the entry delay. The entry delay can be programmed in 10 second
increments from 10 to 150 seconds ("1" = 10 seconds through "15"= 150 seconds). For example, programming a "2" in this location
will produce an entry delay of 20 seconds. (Note: A "0" entry is treated as 0 seconds). Programming a "6" in this location will produce
an entry delay of 60 seconds. Factory default is 30 seconds.
Location 135: Programming The Exit Delay Time
Location 135 contains the number of 10 second increments in the exit delay. The exit delay can be programmed in 10 second
increments from 10 to 150 seconds ("1" = 10 seconds through "15"= 150 seconds). For example, programming a "2" in this location
will produce an exit delay of 20 seconds. (Note: A "0" entry is treated as 0 seconds). Programming a "6" in this location will produce
an exit delay of 60 seconds. Factory default is 60 seconds.
Location 136: Programming The Secondary Entry Delay (Zone Type 7)
Location 136 contains the number of 10 second increments in the entry delay, when an entry delay is initiated by a zone type 7. This
entry delay can be programmed in 10 second increments for 10 to 150 seconds ("1" = 10 seconds through "15" = 150 seconds.
(Note: A "0" entry is treated as zero (0) seconds). Programming a "6" in this location will produce an entry delay of 60 seconds.
(Note: a "0" entry is treated as zero (0) seconds). Programming a "6" in this location will produce an entry delay of 60 seconds.
Factory default is 30 seconds.
Location 137: Programming The Secondary Exit Delay (Zone Type 7)
Location 137 contains the number of 10 second increments after arming, before zone trips will be recognized on a zone type 7. The
exit delay can be programmed in 10 second increments from 10 to 150 seconds ("1" = 10 seconds through "15" = 150 seconds). For
example, programming a "2" in this location will produce an exit delay of 20 seconds. (Note: A "0" entry is treated as zero (0)
seconds). Programming a "6" in this location will produce an exit delay of 60 seconds. If the exit delay time in this location is less
than,
or
equal to that in location 135, zone type 7 will be delayed the amount of time programmed in location 135. (Note: A "0" entry
is treated a zero (0) seconds). Programming a "6" in this location will produce an exit delay of 60 seconds. If the exit delay time in
this location is less than, or equal to that in location 135, zone type 7 will be delayed the amount of time programmed in location 135.
Factory default is 60 seconds.
Location 138: Programming The Siren Shutdown/Recycle Timeout
Location 138 contains the number of 2 minute increments in the automatic cutoff time. The automatic cutoff time can be
programmed in 2 minute increments from 2 to 30 minutes ("1" = 2 minutes through "15" = 30 minutes). For example, programming
a "2" in this location will produce an automatic cutoff time of 4 minutes. (Note: A "0" entry is treated as the factory default of 8
minutes.) Programming a "5" in this location will produce an automatic cutoff time of 10 minutes. NOTE: Please check your state
regulations for the maximum siren time allowed by law. e.g. N.S.W. EPA law currently allows 10 minutes maximum.