25
Location 255: Dynamic Battery Test Duration
The number programmed in location 255 will determine the number of minutes the DL-300E will go into the dynamic
battery
test mode during each 24 hour period. This test removes the A.C. power input and causes the control to function
with the system battery, thus verifying that the battery is capable of performing as designed during an actual power failure.
Factory default is "0" and this feature is not enabled.
COMMUNICATOR CODES
Each of the following communication codes contain four (4) locations referred to as Data 1, Data 2, Data 3 and Data 4. The
first three locations are used for either enabling or disabling and or determining the reporting channel or event number for
the selected communication code. Data 4 is used to determine which phone number(s) is used when Dual or Split reporting
is enabled and or whether that communication event is recorded into the internal event log. Refer to the Data 1, 2, 3, and 4
listing below for more detail.
Only Contact I.D is covered in this manual, for detail on other formats
please refer to the nearest sales branch
.
DATA 1
-
When
Contact
I.D is enabled, Data 1 is used to enable and or select the communicator code for the selected
communicator event. Program in Data 1 the required digit from appendix 1 (options 1 thru 15) to select the required Contact
I.D event report code. Not all communicator codes are programmable in this manner, and only require a "1" in Data 1 to
enable the communicator event report. Refer to the individual communicator code location for further detail.
DATA 2
- When
Contact
I.D is enabled, Data 2 is used to program the 10's digit of the point number.
DATA 3
- When
Contact
I.D is enabled, Data 3 is used to program the 1's digit of the point number.
DATA 4
-
Is used to select phone number (1 = "1 "), phone number (2 = "2") , and the (internal log = "4") or any
combination of the three (3). When Dual or Split reporting is enabled in location 146 then the telephone number
programmed in Data 4 for the selected communicator event is used to report that event. If Dual or Split reporting is not
enabled then program Data 4 to follow telephone number 1 for normal communicator event reporting. I.E. Report via
telephone number 1 and if unsuccessful try telephone number 2. If no Telephone is selected for a given communicator
event that communicator event will not be reported. If (internal log = "4") is enabled then each time that communicator
event is reported it is also recorded into the internal event log for future reference via a LCD Code pad in the smart buss
mode or via the download software.
Note:
The event log can only record communicator events when those communicator
event s are enabled to report. If the event log is required without communicator event reporting, enable the internal log by
programming a "4" in Data 4, and enable the communicator event in Data 1.
Location 256-259: Programming the Communicator Code for Zone 1
Locations 256-259 are used to control the communicator code for zone 1. Zone 1 is automatically enabled and when
contact 1.13 is selected the default report is event "130 - Burglary" with point "01" when in alarm. Refer to appendix 1 if a
different event type is required. The defaults are "3:0:1:5" with telephone number 1 and the event log enabled.
Location 260-263: Programming the Communicator Code for Zone 2
Locations 260-263 are used to control the communicator code for zone 2. Zone 2 is automatically enabled and when
contact I.D is selected the default report is event "130 - Burglary" with point "02" when in alarm. Refer to appendix 1 if a
different event type is required. The defaults are "3:0:2:5" with telephone number 1 and the event log enabled.
Location 264-267: Programming the Communicator Code for Zone 3
Locations 264-267 are used to control the communicator code for zone 3. Zone 3 is automatically enabled and when
contact I.D is selected the default report is event "130 - Burglary" with point "03" when in alarm. Refer to appendix 1 if a
different event type is required. The defaults are "3:0:3:5" with telephone number 1 and the event log enabled.