19
Location 224-239: Programming the Auxiliary Output
Options
Locations 224 through 239 control the output options for the four auxiliary outputs. Each of the four pins has four individual
programming locations that will be referred to in this section as
DATA 1, DATA 2, DATA 3,
and
DATA
4. There are 256 events
or conditions that can be programmed to activate these four auxiliary outputs. The following descriptions of these data locations
will help you to understand how to program each of these locations.
DATA 1 (Source)
-
The number programmed in the
Data 1
location is used to direct the control as to which partitions) will be the
source to initiate the trigger output on each of the four auxiliary outputs. When partitioning is not being used, program a "0" in
this location (factory default = "0"). When partitions are being used, programming selections are as follows: "0" for all Partitions,
"1" for Partition ONE, "2" for Partition TWO, "3" for Partition THREE, and "4" for Partition FOUR. Programming selections for this
location are "0" thru "4".
DATA 2 (Duration)
-
The number programmed in the
Data 2
location represents the amount of time that a trigger output will
remain activated. This duration time is selectable in 2 second increments, from 2 to 28 seconds. For example,
programming a "5" in the data 2 location will create a voltage trigger that would last for 10 seconds (2 x "5" = 10
seconds). Programming a "0" will cause the output to follow the condition. Programming a "15" will latch the trigger
output. Programming selections for this location are the numbers "0" thru "15". NOTE: If you want to change the
increments from seconds to minutes, follow the programming instructions for location 241 to do so, and the duration
time will be selectable from 2 to 28 minutes.
DATA 3 (Category)-
The number programmed in the
Data
3 location will determine the category from which you will select an
activation event. Refer to the following table below to select which category number to program in this location. Programming
selections for this location are "0" thru "15".
DATA 4 (Event)-
The number programmed in the
Data
4 location will determine the actual event in which you Wish to have the
trigger activate upon. Refer to the table below to select which event number to program in this location. Programming selections
for this location are "0" thru "15"
Example 1 - For Pin #1 to follow the "SECURE"
LED for Partition Two, you would enter the following:
In location 224, program a "2" for Partition Two.
In location 225, program a "0" to Follow The Condition,
In location 226, program a "13" for the Category.
In location 227, program an "11" (Secure LED) for the Event.