![background image](http://html1.mh-extra.com/html/daikin/sky-air-b-series-r-410a/sky-air-b-series-r-410a_service-manual_2460071278.webp)
Si21-205
Outdoor Unit (25/35 class)
Removal Procedure
267
3.3
Removal of PCB and Electrical Box
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work
.
Step
Procedure
Points
1. Remove the shelter.
The shelter has five hooks.
Be sure to avoid forgetting to
restore the shelter and to
avoid losing or damaging it.
1
Undo the five hooks
and remove the
shelter.
2. Remove the PCB.
1
Disconnect the ground
wire.