![background image](http://html1.mh-extra.com/html/daikin/sky-air-b-series-r-410a/sky-air-b-series-r-410a_service-manual_2460071267.webp)
FHQ35/50/60BUV1B
Si21-205
256
Removal Procedure
2.2
Removal of Electrical Parts and PC Boards
Procedure
Warning
Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure
Points
1
Loosen the 2 screws of
the control box cover
and remove the control
box cover.
2
Remove the 2 screws
of the control box.
3
Pull down the control
box and let it hang by
the 2 locations in the
rear. Electrical parts
can now be removed.