![background image](http://html1.mh-extra.com/html/daikin/sky-air-b-series-r-410a/sky-air-b-series-r-410a_service-manual_2460071276.webp)
Si21-205
Outdoor Unit (25/35 class)
Removal Procedure
265
3
Remove the three
screws on the left side.
4
Remove the one fixed
screw in the rear of the
top plate. Once lift the
top plate and then
remove it forward.
The left side plate and the
bellmouth can be removed
all at once.
When restoring the top plate,
move it horizontally and get
it down for the easy work.
5
The front plate and the
left side plate can be
removed when the one
fixed screw is removed.
Sectional view at the front.
Step
Procedure
Points
Top plate
Left side
plate
The edge of the top plate
gets into this groove.
(R1737)