Specifications: Carousel Plus W Series
Dehumidifying Dr yers
D e s c r i p t i o n l
2-7
2
Description
APPLICATION NOTES:
All dryers are supplied with an aftercooler/intercooler as standard. The after-
cooler/intercooler reduces the temperature of the return air from the drying
hopper, improving the efficiency of the desiccant. The aftercooler/intercooler
should be connected with the proper water flow rate and temperature to attain
the optimal throughput.
When to use central models
Models W600 - W5000 of Carousel Plus dryers are all configured as central
dryers. Central dryers do not have process heaters. These models should be
used when drying multiple materials that require different drying tempera-
tures. Central models dehumidify the process air, which is then heated to the
correct set point by a Heater Pack, Hopper Temperature Controller (HTC) or
GasTrac Dryer (CGT).
When to use additional filtration
The standard return air cartridge filter is sized for the airflow of each dryer
model and is suited for most applications. You should consider adding an
optional dust collector and/or volatile trap if:
●
The material contains excessive fines. An additional dust collector or cyclone
will extend time between filter cleaning.
●
The material produces volatiles during drying which condense into a waxy or
oily residue. A volatile trap will help to protect the desiccant.
B
A
C
INSTALLATION NOTE:
Wiring between process air heater, Heater Pack, and
dryer where control for this heater is located is not
included. Maximum wire length between dryer and heat
source is 100 feet {30 meters}. Consult Conair or a
qualified electrician to determine gauge of wire required
for distance. Maximum physical distance between dryer
and hopper is 20 feet
{6 meters}.
TPDX019-0713
Summary of Contents for Carousel Plus UGD043-1216
Page 7: ...Table of Contents l v...
Page 8: ...vi l Table of Contents...
Page 48: ...3 24 l Installation Testing...
Page 54: ...4 6 l Operation Control Function Flow Charts continued Login Flow Chart...
Page 55: ...4 O p e r a t i o n Operation l 4 7 Operation Basic Controls...
Page 56: ...4 8 l Operation Control Function Flow Charts continued Operation Flow Chart 1 continued...
Page 58: ...4 10 l Operation...
Page 59: ...Operation Dew Point Package Controls 4 O p e r a t i o n Operation l 4 11...
Page 60: ...Control Function Flow Charts continued Operation Flow Chart 1 4 12 l Operation...
Page 62: ...4 14 l Operation...
Page 63: ...4 O p e r a t i o n Operation l 4 15 Operation Setup Control...
Page 64: ...4 16 l Operation Control Function Flow Charts continued continued Setup Flow Chart 1...
Page 66: ...4 18 l Operation continued Control Function Flow Charts continued Equipment Setup Flow Chart 2...
Page 164: ...6 46 l Troubleshooting...