Problem
Regeneration Low
Temperature
– The regenera-
tion temperature is less than
the low temperature set point
for the specified time.
Defaults are 200°F {93°C} for
20 seconds.
Return Air Temperature
RTD Integrity
– The dryer
continues to run with a passive
alarm.
Possible cause
The regeneration heater has failed.
The output on the control board has
failed or the fuse has blown.
The regeneration RTD is loose or has
fallen out.
There is a loose connection in the wiring
leading to the RTD.
The connection of the RTD plug on the
control board is loose.
The return air RTD has failed.
The control board has failed.
Solution
Check the heater fuses, and resistance
across each leg of the process heater.
Replace the control board or the fuse.
Check the regeneration RTD and tighten
if needed.
Check the RTD plug connections and
make any necessary repairs.
Check the plug connection and tighten if
needed.
Replace the return air RTD.
Replace the control board.
Passive Alarms
If an alarm occurs, a red dialog box is displayed on the dryer’s touch screen
control. The dryer continues to operate, but this problem could prevent cor-
rect drying of your material. The dialog box will indicate whether the alarm
is a shut down alarm or a passive alarm.
Summary of Contents for Carousel Plus UGD043-1216
Page 7: ...Table of Contents l v...
Page 8: ...vi l Table of Contents...
Page 48: ...3 24 l Installation Testing...
Page 54: ...4 6 l Operation Control Function Flow Charts continued Login Flow Chart...
Page 55: ...4 O p e r a t i o n Operation l 4 7 Operation Basic Controls...
Page 56: ...4 8 l Operation Control Function Flow Charts continued Operation Flow Chart 1 continued...
Page 58: ...4 10 l Operation...
Page 59: ...Operation Dew Point Package Controls 4 O p e r a t i o n Operation l 4 11...
Page 60: ...Control Function Flow Charts continued Operation Flow Chart 1 4 12 l Operation...
Page 62: ...4 14 l Operation...
Page 63: ...4 O p e r a t i o n Operation l 4 15 Operation Setup Control...
Page 64: ...4 16 l Operation Control Function Flow Charts continued continued Setup Flow Chart 1...
Page 66: ...4 18 l Operation continued Control Function Flow Charts continued Equipment Setup Flow Chart 2...
Page 164: ...6 46 l Troubleshooting...