11-14
Diagnostic Tools
Writer: Project: Diagnostic Tools Comments:
File Name: O-ch11.doc Last Saved On: 4/22/97 1:11 PM
POST Error Messages
continued
Error Code
Audible
Beeps*
Probable Source of
Problem
Action
1773-Primary Fixed
Disk Port Assignment
Conflict
None
Fixed disk drive error.
Run the System
Configuration Utility
and correct.
1774- Slot x Drive
Array - Obsolete data
found in Array
Accelerator.
Select F1 to discard
contents of Array
Accelerator.
Select F2 to write
contents of Array
Accelerator to drives.
None
SMART-2 Controller error
Data found in Array
Accelerator is older
than data found on
drives. Press F1 to
discard the older data
in the Array
Accelerator and retain
the newer data on the
drives.
1776-Drive Array -
SCSI Port Termination
Error
None
External and internal SCSI
drives are both configured
to Port 1.
Reconfigure drives.
1777-Drive Array -
External Drive
Subsystem Error
None
Cooling fan failure,
internal temperature alert
or open side panel.
Inspect for cooling fan
failure or side panel
open.
1778-Drive Array
resuming Automatic
Data Recovery
process
None
This message appears
whenever a controller
reset or power cycle
occurs while Automatic
Data Recovery is in
progress.
No action necessary.
* L= Long
S = Short
continued