2-21
Compaq ProLiant 5000 Servers Reference Guide
Writer: Compaq Project: Installing the Compaq ProLiant 5000 Server Comments:
File Name: F-ch2.doc Last Saved On: 4/18/97 5:09 PM
Drive Installation Guidelines
The following guidelines should be noted when adding SCSI hard drives:
A maximum of seven SCSI-2 devices may be added per controller.
The SCSI ID for each hot-pluggable hard drive is set as shown in
Figure 2-17.
If only one SCSI hard drive is used it should be installed in the
lowest bay.
Compaq SCSI cables for the Compaq ProLiant 5000 are terminated. Be
sure to remove all terminating jumpers from third-party SCSI devices.
NOTE : Supported Compaq SCSI options are not terminated.
IMPORTANT: When adding a Compaq SMART-2 Array Controller, attach only hot-
pluggable hard drives to the controller.
Figure 2-17. Assigned SCSI IDs