11-29
Compaq ProLiant 5000 Servers Reference Guide
Writer: Project: Diagnostic Tools Comments:
File Name: O-ch11.doc Last Saved On: 4/22/97 1:11 PM
1700 Series -
Fixed Disk Drive Test Error Codes
The 1700 series of Diagnostic error codes identify failures with fixed disk
drive, fixed disk drive controller board, fixed disk drive cabling, and system
board functions. Corrective action may require replacement of the fixed disk
drive cables, fixed disk drive controller board, fixed disk, or system board
assembly. If your system uses a drive array controller, see the section for
Drive Array Advanced Diagnostics (DAAD).
Fixed Disk Drive Test Error Codes
Error Code Range
Possible Corrective Action
1700 - 1799
Run the System Configuration Utility. Loose or defective cable
connections may cause error messages. The fixed disk drive, the fixed
disk drive controller, or the system board may require replacement.
1900 Series -
Tape Drive Test Error Codes
The 1900 series of Diagnostic error codes identify failures with tape cartridge,
tape drive cabling, adapter board, tape drive, or system board assembly.
Corrective action may require replacement of the tape cartridge, tape drive
cabling, adapter board, tape drive, or system board assembly.
Tape Drive Test Error Codes
Error Code Range
Possible Corrective Action
1900-xx ... 1906-xx A defective tape cartridge, loose cable connections, or defective cable
connections may cause error messages. The tape drive, the tape
adapter board, or the system board may require replacement.