11-20
Diagnostic Tools
Writer: Project: Diagnostic Tools Comments:
File Name: O-ch11.doc Last Saved On: 4/22/97 1:11 PM
POST Error Messages
Continued
Error Code
Audible
Beeps*
Probable Source of
Problem
Action
1795-Drive Array -
Array Accelerator
Configuration Error.
Data does not
correspond to this
drive array. Array
Accelerator is
temporarily disabled.
None
This indicates that while
the system was in use,
power was interrupted
while data was in the
Array Accelerator memory.
The data stored in the
Array Accelerator does not
correspond to this drive
array.
1.
Match the Array
Accelerator to the
correct drive
array.
-Or-
2.
Run the System
Configuration
Utility to clear the
data in the Array
Accelerator.
1796-Drive Array -
Array Accelerator Not
Responding.
Array Accelerator is
temporarily disabled.
None
Array Accelerator is
defective or has been
removed.
1.
Check that the
Array Accelerator
is properly
seated.
2.
Run the System
Configuration
Utility to
reconfigure the
Compaq IDA-2
without the Array
Accelerator.
* L= Long
S = Short