Compaq ProLiant 5000 Servers Reference Guide
Writer: Project: Diagnostic Tools Comments:
File Name: O-ch11.doc Last Saved On: 4/22/97 1:11 PM
DAAD Diagnostic Messages
Continued
Error Messages
Possible Corrective Action
DRIVE MONITORING
FEATURES ARE
UNATTAINABLE
DAAD was unable to get the monitor and performance data
due to a fatal command problem such as drive time-out, or
was unable to get the data due to these features not being
supported on the controller. Check for other errors (time-outs,
etc.). If no other errors occur, upgrade the firmware to a
version that supports monitor and performance, if desired.
DRIVE MONITORING IS NOT
ENABLED FOR DRIVE BAY X
The monitor and performance features have not been
enabled. Run the Compaq Diagnostics Utility to initialize the
monitor and performance features.
DRIVE TIME-OUT
OCCURRED ON PHYSICAL
DRIVE BAY X
DAAD issued a command to a physical drive and the
command was never acknowledged. The drive or cable may
be bad. Check the other error messages on the Diagnostics
screen to determine resolution.
DRIVE (BAY) X FIRMWARE
NEEDS UPGRADING
The firmware on this physical drive is below the latest
recommended version. Call your Authorized Compaq Reseller
to obtain the latest upgraded firmware.
DRIVE (BAY) X HAS INVALID
M&P STAMP
The physical drive has invalid monitor and performance data
present. Run the latest Compaq Diagnostics Utility to properly
initialize this drive.
DRIVE X INDICATES
POSITION Y
This message indicates which physical drive appears to be
scrambled or in the wrong drive bay that it was originally
configured for. Examine the graphical drive representation on
DAAD to determine proper drive locations. Remove drive X
and place it in drive position Y. Rearrange the drives
according to the DAAD instructions.
DRIVE (BAY) X RIS COPY
MISMATCH
The copies of the RIS mismatch on this drive do not match.
This drive may need to be replaced. Check for other errors.
DRIVE (BAY) X UPLOAD
CODE NOT READABLE
An error occurred while DAAD was trying to read the upload
code information from this drive. If there were multiple errors,
this drive may need to be replaced.
DUPLICATE WRITE
MEMORY ERROR
Data could not be written to the array accelerator board in
duplicate due to the detection of parity errors. This is not a
data loss situation. Replace the array accelerator board.
continued