11-41
Compaq ProLiant 5000 Servers Reference Guide
Writer: Project: Diagnostic Tools Comments:
File Name: O-ch11.doc Last Saved On: 4/22/97 1:11 PM
DAAD Diagnostic Messages
Continued
Error Messages
Possible Corrective Action
CMOS PRESENT,
CONTROLLER NOT
DETECTED
EISA nonvolatile RAM has a configuration for an array
controller, but there is no board in this slot. Either a board has
been removed from the system, or a board has been placed in
the wrong slot. Place the array controller in the proper slot, or
run the System Configuration Utility to reconfigure nonvolatile
RAM to reflect the removal or new position.
COMPATIBILITY PORT
PROBLEM DETECTED
You have the compatibility port configured for this IDA
controller. When DAAD was verifying this interface, a serious
problem was detected. A hardware problem has occurred and
you should replace the IDA controller.
CONFIGURATION
SIGNATURE IS ZERO
DAAD detected that nonvolatile RAM contains a configuration
signature that is zero. Old versions of the System
Configuration Utility could cause this. Run the latest version of
System Configuration Utility to configure the controller and
nonvolatile RAM.
CONFIGURATION
SIGNATURE MISMATCH
The array accelerator board has been configured for a
different IDA-2 board. The configuration signature on the
array accelerator board does not match the one stored on the
IDA-2 board. To recognize the array accelerator board, run
the System Configuration Utility.
CONTROLLER
COMMUNICATION FAILURE
OCCURRED
DAAD was unable to successfully issue commands to the
controller in this slot. Check the indicators on the controller.
CONTROLLER DETECTED.
CMOS NOT PRESENT
The System nonvolatile RAM is not configured. Run the
System Configuration Utility to configure the nonvolatile RAM.
CONTROLLER FIRMWARE
NEEDS UPGRADING
The controller is below the latest recommended version. Call
your Authorized Compaq Reseller to obtain the latest
upgraded firmware.
CONTROLLER FIRMWARE
NEEDS UPGRADING
(DAAD ERROR 102)
You have the correct controller, however, the IDA firmware
should be greater than 1.26. Call your Authorized Compaq
Reseller to obtain the latest firmware.