11-25
Compaq ProLiant 5000 Servers Reference Guide
Writer: Project: Diagnostic Tools Comments:
File Name: O-ch11.doc Last Saved On: 4/22/97 1:11 PM
Diagnostic Error Codes
The Diagnostic error codes and recommended actions are listed in the
following tables.
IMPORTANT: This information is intended for the user's reference only. Many of
the corrective actions indicated involve complex hardware and/or software changes
and should be performed only by an Authorized Compaq Service Provider.
100 Series -
Primary Processor Test Error Codes
The 100 series of Diagnostic error codes identify failures with processor and
system board functions. Corrective action may require replacement of system
boards or processor assemblies (either processor cards or system boards that
include the processor).
Primary Processor Test Error Codes
Error Code Range
Possible Corrective Action
100-xx ... 106-xx
The processor assembly may require replacement.
107-xx ... 109-xx
The battery/clock module or system board may require replacement.
110-xx ... 113-xx
The system board may require replacement.
114 - xx
A loose or defective speaker assembly may cause this error. The
speaker assembly or the system board may require replacement.
122-xx ... 123-xx
The processor assembly may require replacement.