11-27
Compaq ProLiant 5000 Servers Reference Guide
Writer: Project: Diagnostic Tools Comments:
File Name: O-ch11.doc Last Saved On: 4/22/97 1:11 PM
400 Series - Parallel Printer Test Error Codes
The 400 series of Diagnostic error codes identify failures with parallel printer
interface card or system board functions. Corrective action may require
replacement of the serial/parallel interface board or the system board
assembly.
Parallel Printer Test Error Codes
Error Code Range
Possible Corrective Action
400-xx ... 403-xx
Run the System Configuration Utility. Loose or defective cables may
cause error messages. The parallel interface board or the system board
may require replacement.
600 Series - Diskette Drive Test Error Codes
The 600 series of Diagnostic error codes identify failures with diskette,
diskette drive, or system board functions. Corrective action may require
replacement of the diskette, the diskette drive, or the system board assembly.
Diskette Drive Test Error Codes
Error Code Range
Possible Corrective Action
600-xx ... 698-xx
A defective diskette, loose cables, or defective cables may cause error
messages. The diskette drive or system board may require replacement.
699-xx
1. Replace the diskette and retest.
2. Run the System Configuration Utility.