11-15
Compaq ProLiant 5000 Servers Reference Guide
Writer: Project: Diagnostic Tools Comments:
File Name: O-ch11.doc Last Saved On: 4/22/97 1:11 PM
POST Error Messages
Continue
d
Error Code
Audible
Beeps*
Probable Source of
Problem
Action
1779-Drive Array
Controller detects
replacement drives
None
Intermittent drive failure
and/or possible loss of
data.
If this message
appears and drive
X
has not been replaced,
this indicates an
intermittent drive
failure. This message
also appears once
immediately following
drive replacement
whenever data must
be restored from
backup.
1780-Disk 0 Failure
None
Hard drive/format error.
Run Diagnostics.
Contact your service
provider
1781-Disk 1 Failure
None
Hard drive/format error
Run Diagnostics.
Contact your service
provider
1782-Disk Controller
Failure
None
Hard disk drive circuitry
error
Run Diagnostics.
Contact your service
provider
1784-Drive Array
Drive Failure, Physical
Drive
None
Defective drive and/or
cables
Check for loose cables.
Run Diagnostics.
Contact your service
provider.
1785-Drive Array not
Configured
None
Configuration error
Run the System
Configuration Utility
and correct.
* L= Long
S = Short
continued