2-19
Compaq ProLiant 5000 Servers Reference Guide
Writer: Compaq Project: Installing the Compaq ProLiant 5000 Server Comments:
File Name: F-ch2.doc Last Saved On: 4/18/97 5:09 PM
2. Turn OFF any peripheral devices.
3. Disconnect the AC power cord and any peripheral devices.
4. Open the front bezel, then remove the Side Access Panel by loosening
three thumb screws on the left and sliding the Side Access Panel
forward.
5. Set the SCSI ID for the storage device. (See the User Guide that
accompanies the specific option.)
6. Remove the terminating resistors.
7. Remove the blank panel from the vacant drive position.
8. Slide the device onto the drive bridge rails and secure with screws.
9. Attach power and signal cables to the device. (See the User Guide for
the specific option.)
10. Reinstall the Side Access Panel and the front bezel.
11. Reconnect the AC power cord and any peripheral devices.
12. Turn ON the power to any peripheral devices.
13. Turn ON the power to the server.
Figure 2-15. Installing a DAT tape drive in drive bay 5