11-19
Compaq ProLiant 5000 Servers Reference Guide
Writer: Project: Diagnostic Tools Comments:
File Name: O-ch11.doc Last Saved On: 4/22/97 1:11 PM
POST Error Messages
Continued
Error Code
Audible
Beeps*
Probable Source of
Problem
Action
1792-Drive Array
Reports Valid Data
Found in Array
Accelerator.
Data will
automatically be
written to drive array.
None
This indicates that while
the system was in use,
power was interrupted
while data was in the
Array Accelerator memory.
Power was then restored
within eight to ten days,
and the data in the Array
Accelerator was flushed to
the drive array.
No action necessary;
no data has been lost.
Perform orderly system
shut-downs to avoid
data remaining in the
Array Accelerator.
1793-Drive Array -
Array Accelerator
Battery Depleted -
Data Lost
(Error message 1794
also displays.)
None
This indicates that while
the system was in use,
power was interrupted
while data was in the
Array Accelerator memory.
Array Accelerator batteries
failed. Data in Array
Accelerator has been lost.
Power was not
restored within eight
to ten days. Perform
orderly system shut-
downs to avoid data
remaining in the Array
Accelerator.
1794-Drive Array -
Array Accelerator
Battery Charge Low.
Array Accelerator is
temporarily disabled.
Array Accelerator will
be re-enabled when
battery reaches full
charge.
None
This is a warning that the
battery charge is below
75%. Posted writes are
disabled.
Run Diagnostics.
Contact your service
provider.
* L= Long
S = Short
continued