11-17
Compaq ProLiant 5000 Servers Reference Guide
Writer: Project: Diagnostic Tools Comments:
File Name: O-ch11.doc Last Saved On: 4/22/97 1:11 PM
POST Error Messages
Continue
d
Error Code
Audible
Beeps*
Probable Source of
Problem
Action
*1788-Incorrect Drive
Replaced: Drive
X
Drive(s) were
incorrectly replaced:
Drive
Y
Select "F1" to
continue - drive array
will remain disabled.
Select "F2" to reset
configuration - all
data will be lost.
None
Drives are not installed in
their original positions, so
the drives have been
disabled.
See
note below.
Reinstall the drives
correctly as indicated.
Press F1 to restart the
computer with the
drive array disabled.
-Or-
Press F2 to use the
drives as configured
and lose all the data
on them.
*NOTE : The 1788 error message might also be displayed inadvertently due to a bad power
cable connection to the drive or by noise on the data cable. If this message was due to a
bad power cable connection, but not due to an incorrect drive replacement, repair the
connection and press F2.
-Or-
If this message was not due to a bad power cable connection, and no drive replacement
took place, this could indicate noise on the data cable. Check cable for proper routing.
* L= Long
S = Short
continued