11-3
Compaq ProLiant 5000 Servers Reference Guide
Writer: Project: Diagnostic Tools Comments:
File Name: O-ch11.doc Last Saved On: 4/22/97 1:11 PM
POST Error Messages
Continued
Error Code
Audible
Beeps*
Probable Source of
Problem
Action
170-EISA Expansion
Device Not
Responding
None
EISA Expansion board
failure
Contact your service
provider.
172-EISA
Configuration
Nonvolatile Memory
Invalid
None
Nonvolatile configuration
corrupt or jumper
installed.
Run the System
Configuration Utility
and correct.
172-1 Configuration
Nonvolatile Memory
Invalid
None
Nonvolatile configuration
corrupt.
Run the System
Configuration Utility
and correct.
173-EISA Slot ID
Mismatch
None
Board replaced,
configuration not updated.
Run the System
Configuration Utility
and correct.
174-EISA
Configuration/Slot
Mismatch Device Not
Found
None
EISA board not found.
Run the System
Configuration Utility
and correct.
175-EISA
Configuration/Slot
Mismatch Device
Found
None
EISA board added,
configuration not updated.
Run the System
Configuration Utility
and correct.
176-Slot with Not
Readable ID Yields
Valid ID
None
EISA board in slot that
should contain an ISA
board.
Run the System
Configuration Utility
and correct.
* L= Long
S = Short
continued