POST Error Messages
continued
Error Code
Audible
Beeps*
Probable Source of
Problem
Action
1769- Slot x Drive
Array - Drive(s)
disabled due to
failure during expand.
Select F1 to continue
with logical drives
disabled.
Select F2 to accept
data loss and to re-
enable
logical drives.
None
SMART-2 Controller error
Data has been lost
while expanding the
array, therefore the
drives have been
temporarily disabled.
Press F2 to accept the
data loss and re-
enable the logical
drives. Restore data
from backup.
1771-Primary Disk
Port Address
Assignment Conflict
None
Internal and external hard
drive controllers are both
assigned to the primary
address.
Run the System
Configuration Utility
and correct.
1772-Secondary Disk
Port Address
Assignment Conflict
None
Address Assignment
Conflict. Internal and
external hard drive
controllers are both
assigned to the
secondary address.
Run the System
Configuration Utility
and correct.
* L= Long
S = Short
continued