Eclipse
|
Upgrade Guide
Page 152
2.
Remove the MVX serial cable (CAB-MVX-48Z).
3.
Remove jumper J1000.
4.
Repeat steps 7 through 11 for each remaining E-MADI64 card.
11.3
Upgrading the E-MADI64 application, DSP and
FPGA code using EHX
You can upgrade the E-MADI64 application, DSP and FPGA code using EHX and an
Eclipse matrix. If you are using an Ethernet connection, an EHX configuration map is
required with the correct IP address configured.
Note:
With E-MADI64, you can upgrade the FPGA code in exactly the same way as the
application and DSP code
.
*.fwc
format files are used in the download of the E-MADI64 application code, the DSP
code, and the FPGA code. The Drivers USB contains the E-MADI64 application and DSP
code:
•
Drivers USB > ECLIPSE DRIVERS > Omega-Median-Delta > E-MADI Application
•
Drivers USB > ECLIPSE DRIVERS > Omega-Median-Delta > E-MADI DSP
The Drivers USB contains the E-MADI64 FPGA code:
•
Drivers USB > ECLIPSE DRIVERS > Omega-Median-Delta > E-MADI FPGA
Place the application, DSP and FPGA code files in a location that EHX can access. When
these files are downloaded to the matrix,
all
the E-MADI64 cards that have been fitted
to the matrix will be upgraded.
Note
–
Once the firmware is downloaded from EHX to the CPU card it can take between
45
–
60 minutes to transmit this image to the MADI cards (depending on the number of
cards that are inserted and therefore receiving the image in parallel). Please use the
matrix event log of the matrix frame to monitor the percentage complete state of the
image transmission. Allow the card to automatically reboot at the end of upgrade as the
image has to be copied to permanent storage on the card after it has been received.
Tip:
For help with selecting the other procedures you require for upgrading to Eclipse HX
v9.1, see the quick reference procedures tables in
2 Selecting Upgrade Procedures
.
To upgrade E-MADI64 H8, DSP or FPGA code using EHX:
1.
Ensure that you have the following equipment:
Required equipment
Description / comments