Eclipse
|
Upgrade Guide
Page 169
4.
From the Tera Term main screen select
Setup > Serial port…
.
The serial port setup screen should now be visible. Configure Tera Term with the
following settings:
Field
Setting
Baud
19200
Data
8 bit
Parity
None
Stop
1 bit
Flow Control
None
Table 14-3: Serial port setup screen settings
Note:
Do not configure (ignore) the Transmit delay settings.
Click
OK
.
5.
Power up the i-Station panel into maintenance mode by first holding in the
recessed button found on the rear panel during a simultaneous AC power up.
The reset button must be held in until all front panel keys turn
bright red
and
the front panel display modules show the message
Display Module Test’, Press
All Buttons 3x
.
Tip:
If the recessed button cannot easily be accessed, use a bent paper clip or
small flat blade screwdriver to press the button in.
Figure 14-6: Module display message