Eclipse
|
Upgrade Guide
Page 75
For the second device, select the U1 CPLD code. The U1 CPLD code for the CPU
card is available from the Drivers USB:
•
Drivers USB > ECLIPSE DRIVERS > Omega-Median-Delta > xxxxxx
- Config Card U1 CPLD code
.
Note:
xxxxxx represents the part number.
The folder contains a CPLD code file (
*.jed
) and a
Read Me
file (
*.txt
), which
contains version information.
10)
A summary dialog is presented. For
all
devices, ensure that the
Erase Before
Programming
and
Verify
flags are set. Click
OK
.
Figure 5-18: Example Xilinx device programming properties
11)
Right click the second device and select
Programming
.
The upgrade starts, and takes approximately 2 minutes to complete. When the
upgrade is complete, the
Program Succeeded
message is displayed in the
main window.
12)
Power down the CPU card.
5.11
Downloading a test configuration to the CPU card
using EHX
After you have upgraded your Eclipse HX-Median / Eclipse HX-Omega / Eclipse HX-Delta
matrix CPU cards, Clear-Com recommends downloading a test configuration from EHX to
the CPU cards.
Downloading a configuration will enable you to make any further configuration changes
to the cards using either a serial or Ethernet connection.
For more information, see your
EHX User Manual
.