Eclipse
|
Upgrade Guide
Page 151
7.
On the E-MADI64 card to be updated, ensure that jumper
J1000
is made.
Figure 11-3: E-MADI64 PCB (upper right hand corner)
8.
Connect the MVX serial cable (
CAB-MVX-48Z)
between the COM port on the PC and
the
CON1001
on the E-MADI64 card to be updated.
Figure 11-3: E-MADI64 PCB (upper right hand corner)
Note:
The E-MADI64 connection is polarized to ensure a correct connection.
9.
Insert the E-MADI64 card into the Eclipse HX-Median / Eclipse HX-Omega /
Eclipse HX-Delta matrix (having ensured that the matrix is powered on).
10.
Select
Program Flash
from the FDT. Confirm that FDT reports the image has
been written successfully.
Important note:
If the E-MADI64 card fails to upgrade, reset (re-seat) the E-MADI64 card and
select Program Flash from the FDT again.
If you are using a USB-to-serial adaptor, the adaptor may have to be unplugged
and re-plugged to enable the upgrade to start on some computers. If you are
running the EHX application, ensure that EHX is configured for Ethernet and not
serial connection. When the upgrade is complete, you can also do the following:
1.
Remove the E-MADI64 card from the matrix.