Eclipse
|
Upgrade Guide
Page 135
be seen on the serial console. This reset is essential, as it permits Tera Term to interrupt the
boot process.
15. If the reset is successful, the following dialog is displayed:
Figure 9-13: E-QUE (MK2) successful reset dialog
To continue, click
OK
.
Note:
If the reset and reboot is not successful, the following error message is displayed:
Figure 9-14: E-QUE (MK2) reset error message
If you receive this message, you are advised to repeat the procedure from Step 6.
16. The boot countdown appears again on the serial console. Tera Term recognizes that the card
has rebooted and you are asked to enter the following information to enable the download:
a. Enter an IP address for the E-QUE card. This address must be in the same range
as your PC IP address (for example,
192.168.42.5
).
b. Enter your PC IP address (for example,
192.168.42.1
).
c. Enter the file name of the E-QUE card application code (firmware) (for example,
eque_release_image-3.16.5.0
).
d. Enter the Gateway IP address or accept the default (
10.50.16.1
).
e. Enter the Subnet Mask or accept the default (
255.255.255.0
).
The application code downloads to the E-QUE card (MK2). When the download is complete,
the E-QUE card (MK2) reboots.
Note:
If when downloading file, T T T T is displayed on the Tera Term serial screen, this indicates a
problem downloading the file. Check the network connection and the IP addresses that were