Eclipse
|
Upgrade Guide
Page 61
Required equipment
Description / comments
Standard RS232 serial
cable (9-pin D-Type to 9-
pin D-Type)
-
Tera Term installation
Tera Term must be configured and
operational. You can find the Tera Term
application on both of the Eclipse HX 9.0
upgrade media:
Software USB > SOFTWARE - EHX.xxx >
SOFTWARE - EHX.xxx >
3rd_Party_Software > Teraterm
Drivers USB > ECLIPSE DRIVERS >
3rd_Party_Software > Teraterm
An EHX configuration file
(*.hxn or *.ccn format)
The configuration file must have the
appropriate IP addresses set.
The appropriate *.fwr data
file for the CPU card
application
You can find the
*.fwr
data file on the
software USB:
Software USB > SOFTWARE - EHX.xxx >
SOFTWARE - EHX.xxx > Eclipse HX-
Omega-Median-Delta > xxxxxx
–
Config
Card Application
(where
xxxxxx
represents the part number).
Table 5-3: Required equipment
2)
Install the Tera Term application
.
Accept all default settings.
Tip:
To find out how to install Tera Term, see
3)
Start Tera Term. In the
New Connection
dialog, select
Serial
(connection) and
the COM port to use. Click
OK
.
Figure 5-5: Tera Term: selecting serial connection